M&C TechGroup MP47-Z_Ex Operator's manual Benutzerhandbuch

Seite 86

Advertising
background image

KNF Motor M 56 Ex

Use

Translation of orignal Operating and Installation Instructions, english, KNF 121220-121648 01/13

6

2.4.5. Types of protection

Marking

Description

d Flameproof

enclosure

e Increased

safety

i Intrinsic

safety

p Pressurization
m Encapsulation
o Oil

immersion

q Sand

filling

nA Non

sparking

nC Several

meanings

nR

Vapor proof housing

nL Energy-limited

(varies between North America and Europe)

nP Simplified

pressurization

Tab. 7

2.4.6. Equipment protection level

Marking

Description

Ga

Device with a “very high” protection level

Gb

Device with a “high” protection level

Gc

Device with “extended” protection level

Tab. 8