Design and function – M&C TechGroup MP47-Z_Ex Operator's manual Benutzerhandbuch

Seite 39

Advertising
background image

Diaphragm Pumps PJ19423-726

Design and function

Translation of Original Operating- and Installation Instructions, english, KNF PJ19423-726 02/13

11

5. Design and function

Design

1 Outlet
2 Inlet
3 Capacitor
4 Pump

head

5 Pump type plate
6 Motor
7 Motor type plate

Fig. 1: Diaphragm pump (shown with motor from KNF)

Function

1 Outlet

valve

2 Inlet

valve

3 Transfer

chamber

4 Diaphragm
5
Eccentric
6 Connecting rod
7 Pump

drive




Fig. 2: Pump head

The pumps transfer, compress and evacuate gases and vapors.

The elastic diaphragm (4) is moved up and down by the eccentric
(5) and the connecting rod (6). In the downward stroke it aspirates
the gas to be transferred via the inlet valve (2). In the upward
stroke, the diaphragm presses the medium out of the pump head
via the outlet valve (1). The transfer chamber (3) is hermetically
separated from the pump drive (7) by the diaphragm.

The pumps can be used as vacuum pump or compressor. How-
ever, pressure and vacuum cannot be generated simultaneously.

1 2 3

4 5 6 7