Altosonic v modbus handbuch seite 56 von 57 – KROHNE ALTOSONIC V Modbus DE Benutzerhandbuch
Seite 56

ALTOSONIC V
Modbus Handbuch
Seite 56 von 57
0x11, 0xD1, 0xD0, 0x10, 0xF0, 0x30, 0x31, 0xF1, 0x33, 0xF3,
0xF2, 0x32, 0x36, 0xF6, 0xF7, 0x37, 0xF5, 0x35, 0x34, 0xF4,
0x3C, 0xFC, 0xFD, 0x3D, 0xFF, 0x3F, 0x3E, 0xFE, 0xFA, 0x3A,
0x3B, 0xFB, 0x39, 0xF9, 0xF8, 0x38, 0x28, 0xE8, 0xE9, 0x29,
0xEB, 0x2B, 0x2A, 0xEA, 0xEE, 0x2E, 0x2F, 0xEF, 0x2D, 0xED,
0xEC, 0x2C, 0xE4, 0x24, 0x25, 0xE5, 0x27, 0xE7, 0xE6, 0x26,
0x22, 0xE2, 0xE3, 0x23, 0xE1, 0x21, 0x20, 0xE0, 0xA0, 0x60,
0x61, 0xA1, 0x63, 0xA3, 0xA2, 0x62, 0x66, 0xA6, 0xA7, 0x67,
0xA5, 0x65, 0x64, 0xA4, 0x6C, 0xAC, 0xAD, 0x6D, 0xAF, 0x6F,
0x6E, 0xAE, 0xAA, 0x6A, 0x6B, 0xAB, 0x69, 0xA9, 0xA8, 0x68,
0x78, 0xB8, 0xB9, 0x79, 0xBB, 0x7B, 0x7A, 0xBA, 0xBE, 0x7E,
0x7F, 0xBF, 0x7D, 0xBD, 0xBC, 0x7C, 0xB4, 0x74, 0x75, 0xB5,
0x77, 0xB7, 0xB6, 0x76, 0x72, 0xB2, 0xB3, 0x73, 0xB1, 0x71,
0x70, 0xB0, 0x50, 0x90, 0x91, 0x51, 0x93, 0x53, 0x52, 0x92,
0x96, 0x56, 0x57, 0x97, 0x55, 0x95, 0x94, 0x54, 0x9C, 0x5C,
0x5D, 0x9D, 0x5F, 0x9F, 0x9E, 0x5E, 0x5A, 0x9A, 0x9B, 0x5B,
0x99, 0x59, 0x58, 0x98, 0x88, 0x48, 0x49, 0x89, 0x4B, 0x8B,
0x8A, 0x4A, 0x4E, 0x8E, 0x8F, 0x4F, 0x8D, 0x4D, 0x4C, 0x8C,
0x44, 0x84, 0x85, 0x45, 0x87, 0x47, 0x46, 0x86, 0x82, 0x42,
0x43, 0x83, 0x41, 0x81, 0x80, 0x40
} ;
9.4
Anhang D: COMS0300.DAT
Beispiel fur ALTOSONIC V system
-------------------------------------------------------------------------------------------------------------------------------------------
1<1 UFC500 COMMUNICATION SETUP>
1.1 UFC_UART_BASEADDRESS
=#3E8 // COM1=0x3F8, COM2=0x2F8
// COM3=0x3E8, COM4=0x2E8
1.2 UFC_UART_INTERRUPT
=#4 // 3 OR 4, (IRQ3=COM2/4) (IRQ4=COM1/3)
1.3 UFC_UART_BAUDRATE
=#28800 // DO NOT CHANGE !
1.4 UFC_UART_RTS_MODE
=#0 // ENABLE TRANSMITTER WITH LOGICAL 0 OR 1
-------------------------------------------------------------------------------------------------------------------------------------------
2<PRINTER COMMUNICATION SETUP>
2.1 PRINTER_COMPORT
=#1 //1,2,3,4
2.2 PRINTER_WORD_LENGTH
=#8 //7 or 8
2.3 PRINTER_PARITY
=#2 //0=disabled,1=odd,2=even
2.4 PRINTER_STOP_BITS
=#1 //1 or 2
2.5 PRINTER_BAUDRATE
=#9600 //38400, 19200, 9600, 4800, 2400, 1800
//1200, 600, 300, 200, 150, 134.5, 110, 75
2.6 PRINTER_DTR_POLARITY
=#1 //0=pos,1=neg
2.7 PRINTER_RTS_POLARITY
=#1 //0=pos,1=neg
2.8 PRINTER_TIMEOUT
=#5000 //Timeout[ms] on acknowledges etc.
2.9 PRINTER_TIMEOUT_MANAGE
=#10 //Timeout[ s] for print management switch
-------------------------------------------------------------------------------------------------------------------------------------------
3<MODBUS COMMUNICATION SETUP>
3.1 MODBUS_UART_BASEADDRESS =#2E8 // COM1=0x3F8, COM2=0x2F8
// COM3=0x3E8, COM4=0x2E8
3.2 MODBUS_UART_INTERRUPT
=#3 // 3,4 : (IRQ3=COM2/4) (IRQ4=COM1/3)
3.3 MODBUS_UART_BAUDRATE
=#9600 // 1200,2400,4800,9600,19200
3.3 MODBUS_UART_RTS_MODE
=#0 // 0,1 : ENABLE TRANSMITTER LOGICAL 0 OR 1
3.4 MODBUS_UART_N_DATABITS =#8 // 7,8 : NUMBER OF DATABITS
3.5 MODBUS_UART_N_STOPBITS =#1 // 1,2 : NUMBER OF STOPBITS
3.6 MODBUS_UART_PARITY
=#0 // 0..2: PARITY 0=NONE,1=ODD,2=EVEN
3.7 MODBUS_UART_HALF_DUPLEX =#0 // 0,1 : 0=FULL_DUPLEX,1=HALF DUPLEX
3.8 MODBUS_TRANSFER_MODE =#1 // 0,1 : 0=ASCII 1=RTU
-------------------------------------------------------------------------------------------------------------------------------------------
4<SYSTEM CHECK>
4.1 DISPLAY_SYSTEM_INTERRUPTS =#1
// 0,1 : 0=NO 1=YES
4.2 LOG_RECEIVED_DATA
=#0
// 0..10240 : 0=NO to 10240 KB
-------------------------------------------------------------------------------------------------------------------------------------------
5<MODBUS TYPE DEFINITION >
5.1 MODBUS_DEVICE_TYPE
=#1 // 1,2 : 1=SLAVE 2=MASTER
5.2 MODBUS_MODICON_COMPAT. =#1 // 0,1 : 0=NOT MODICON COMPATIBLE
// 1=MODICON COMPATIBLE
5.3 MODBUS_SLAVE_ID
=#1 // 0.. 247
5.4 FLAG_HOLD_TIME
=#90 // N * 35 ms flag hold time.