Configuration level, 4 functions and operation – JUMO 707020 dTRANS T02 LCD - Four-Wire Transmitter Operating Manual Benutzerhandbuch
Seite 51

13
4 Functions and operation
Configuration level
You can access the configuration level from the parameter level by
pressing the
q button (for at least 2 seconds).
The following functions can be programmed at this level:
- Probe type
C111
- Linearization
C112
- Number of decimal places
C113
- Unit of measurement
C002
- Supply frequency and temperature compensation
C114
- Fixed value for temperature compensation
C115
- Measurement display
C116
- Function of the analog output
C211
- Signal on probe break/short-circuit
C212
- Function of the logic output 1
C221
- Signal on probe break/short-circuit
C222
- Lower switching differential (hysteresis)
C223
- Upper switching differential (hysteresis)
C224
- Function of the logic output 2
C231
- Signal on probe break/short-circuit
C232
- Lower switching differential (hysteresis)
C233
- Upper switching differential (hysteresis)
C234
H
The parameters can only be modified when the parameter
OFFS is active in the display and the configuration level has
been started. If another parameter is active, you can only
read the current setting.