Operation SmartCore battery

Audible:

To check the capacity, simply press the touch-

pad once. At first an audible signal will sound,

which is especially useful while using the

battery mounted on a helmet or headband,

to give a quick reading in 20% steps.

Capacity Indicator

Taillight

To run the taillight simply

press the touch pad two times

and the 5 LEDs will

operate continuously. To switch off the taillight, simply press the pad again.

Moving light:

Press the touch pad three times

to activate the moving light. To switch it off

press the button another time.

Example:

3 LEDs

steady glow

(20 %, 40 %, 60 %)

1 LED

blinking

(80 %)

Visible:

The visible indicator uses 5 red LEDs. The LEDs can operate in two different

operating states: blinking and continuous. LED meanings:

A blinking LED

is indicating a 10% step and a continuously glowing LED a 20% step.

5 x

= 100 %

4 x

= 80%

3 x

= 60%

2 x

= 40%

1 x

= 20%

= 70 % remaining capacity

Battery voltage

(once per Volt)

Battery voltage

(once per 1/10 Volt)

After connecting the lamp to the battery, the software runs a selftest; the

lamp itself as well as the red and blue LEDs in the switch light up once.

The

battery voltage

is then indicated by the blue and red LEDs, as follows:

The blue LED flashes once for each volt; and then

the red LED flashes once for each 1/10 of a volt.

To display the battery voltage again, unplug the light from the battery

and then plug it in again.

Note:

To deactivate this display, simply press the button. In other

words, you needn't let the display go through its whole cycle in order
to use the lamp.

The control electronics measures the voltage under load.
Thus, measurements using a voltmeter will not be comparable.

Example:

The blue LED flashes seven times and the red LED then

flashes five times; this means that the measured voltage under load

is 7.5 V.

This display helps you assess the actual state of the battery

prior to use.

Initialization & voltage display:

battery is fully charged:

more than 8.0 V

battery needs charging or is old:

7.1 to 7.8 V

battery is not ready for use:

6.5 to 7 V

Interpreting the voltage display: