Troubeshooting, Technical data, Deut sc h engli sh – Lupine Piko 1200 Lumens - 13W Benutzerhandbuch

Seite 21: Problem, Cause, Solution

Advertising
background image

40

41

Piko

Piko

Deut

sc

h

Engli

sh

Troubeshooting

3

3

Battery life varies according to battery age and condition,

as well as ambient temperature.

Default setting

Piko lamp:

55 g

Piko 4 with battery:

180 g

Piko 7 with battery:

300 g

Piko U4 with battery:

180 g

Piko X4 with battery:

210 g

Piko X7 with battery:

330 g

Piko X Duo with (single) battery: 180 g

Weight:

Input voltage: 100 – 240 V~, 50 – 60 Hz
Charging current:

up to 1.2 A

Compatible batteries: Li-Ion 7.2 V

Charger Wiesel:

13 W 1200 lumens

6 W 650 lumens

4 W 450 lumens

2 W 240 lumens

1 W 120 lumens

0.3 W 40 lumens

Light output:

Battery life:

4 hours

9 hours

12 hours

24 hours

42 hours

160 hours

2 hours

4 hours

6 hours

12 hours

21 hours

80 hours

2 hours 40 min.

5 hours

7 hours

14 hours

28 hours

95 hours

Piko 7 / X7:

Piko X Duo (two batteries)

Piko 4 / X4 / U4:

Lens beam angle:

Operating temperature:

22 °

Piko 4/X4:

3.3 Ah / 7.2 V Li-Ion

Piko 7/X7:

6.6 Ah / 7.2 V Li-Ion

Piko X Duo: 2 x 2.0 Ah / 7.2 V Li-Ion

-25 °C to +70 °C

Piko 4/X4:

3 hours

Piko 7/X7:

5:30 hours

Piko X Duo: 2 hours (per battery)

Battery capacity/nominal voltage:

Charging time:

IP68

Protection class:

Technical data

Problem

The light does not come on
and the power LEDs do not
flash when the battery is
plugged into the lamp.

With the battery plugged in,
the power LEDs do not come
on, but the PCS LEDs flash.

The runtime is too short.

Even after charging only
the 20% LED will light up
at the Smartcore battery.

Cause

Extremely discharged battery.

Battery not plugged into the

light or not plugged in

properly.

Faulty LED unit.

Discharged battery.

Old battery.

Very low ambient

temperature.

Faulty charger.

Unsuitable battery.

The indicator was reseted

Solution

Charge the battery.

Check all plug contacts.

LED unit needs replacement.

Get in touch with Lupine.

Charge battery.

Replace battery.

Keep battery warm.

Replace charger.

Use original Lupine battery.

Discharge the battery with

your light and fully charge it
afterwards.

In case the problem still

exists.

www.lupine.de/videos/support
For further information how to
recalibrate a battery.

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: