Installation / Preparation for commissioning

28

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland

Telefon +49 711 3409-0, Telefax +49 711 3409-133, E-Mail: [email protected]

English

5.5.1 Supply voltage, X1

NOTICE

Risk of undetected damage to the internal
electronics due to incorrect overvoltages!

If an overvoltage of >36 VDC is applied inadvertently,

the measuring system must be inspected on site.

The measuring system must be taken out of

service immediately

If returning the measuring system, the reasons or

circumstances under which the overvoltage
occurred should be stated

The power supply must satisfy the requirements

in accordance with SELV/PELV (IEC 60364-4-
41:2005)


PIN Signal

Description

1

+ 24 VDC (11…28 VDC)

Supply voltage

PIN 1/2

through-connected

2

+ 24 VDC (11…28 VDC)

Supply voltage

3 0

V

GND

PIN 3/4

through-connected

4 0

V

GND


Optical sensing unit and magnetic sensing unit have a common supply, but are
electrically isolated internally via two separate power supplies.