6 technical data, 1 conditions of use, 2 conformity to standards and directives – Burkert Type 8025 Benutzerhandbuch
Seite 12: 3 general technical data, 1 mechanical data, Technical data, Conditions of use, Conformity to standards and directives, General technical data, Mechanical data

10
Technicaldata
6
TEchNIcAL DATA
6.1
conditions of use
Ambient temperature
-10 to +60 °C
Air humidity
< 80 %, non condensated
Height above see level
max. 2000 m
Installation class
Class I acc. to UL 61010-1
Degree of pollution
Degree 2 acc. to EN 61010-1
Protection rating
• wall-mounted version
• panel version
acc. to EN 60529
• IP65, device wired, cable glands tightened, cover lid screwed tight and
entry item nuts of the cable glands tightened at a screwing torque of
1.5 Nm.
• front side IP65, rear side IP20
6.2
conformity to standards and directives
The device conforms to the EC directives through the following standards:
• EMC: EN 61000-6-2, EN 61000-6-3
• LVD: EN 61010-1
• Environnemental testing: Vibration: EN 60068-2-6, Shock: EN 60068-2-27.
The UL devices with PU01 variable key comply with the following standards:
• UL 61010-1
• CAN/CSA-C22.2 n° 61010-1
6.3
General technical data
6.3.1
mechanical data
part
material
Housing with cover, wall-mounted version
ABS
Cable glands, wall-mounted version
PA
Open housing, panel version
PC
Foil
polyester
4 screws
Stainless steel
Cable clips
PA
English
Type 8025 UNIVERSAL