3 specifications of the connected flow sensor, 4 electrical connection, Specifications of the connected flow sensor – Burkert Type 8025 Benutzerhandbuch
Seite 15: Electrical connection

13
Technicaldata
6.3.3
Specifications of the connected flow sensor
Signal originating from the remote sensor
• type
• frequency
• max. voltage
• pulse, sine-wave (typical sensitivity 50 mV peak-
to-peak at 250 Hz), "on/off", or standard voltage
0-5 V DC
• 0,6 Hz to 2,2 kHz, can be adjusted
• 36 V DC
Input impedance
depends on the position of selector "LOAD" on the
electronic board of the 8025. See chap. “7.4.10”
Power supply
supplied by the transmitter depending on the position
of selector "SENSOR SUPPLY" of the 8025, either:
• 5 V DC, 30 mA max.
• (L+)-12V: supply voltage (L+) of the transmitter
minus 12 V DC (minus 12,5 V DC max.), 80 mA max.
• L+: supply voltage (L+) of the transmitter (minus
1,5 V DC max.), 140 mA max. (if the device is ener-
gized with 12-36 V DC), 80 mA max. (if the device is
energized with 115/230 V AC)
6.3.4
Electrical connection
Type of connection
on the terminal blocks of the electronics (and through
cable glands M16x1,5, for the wall-mounted versions)
Cable specifications
• cable type
• Cross section of wires
• Diameter of each cable (for the cable glands
M16x1,5 of the wall-mounted version)
• shielded
• 0.2 to 1.5 mm
2
• 4 to 8 mm
English
Type 8025 UNIVERSAL