When using a float made of titanium in areas exposed to

danger of explosion of category 1/2, please make sure,

during installation and operation, that the said float will

generate no sparks caused by friction or shock.

Maximum lengths of guide tubes

Depending on the length and design of the guide tube, the

level sensor must be fixed to the container bottom

(see table).

12

WIKA operating instructions level sensor model FFG

13445627.01 12/2010 GB/D/F

4. Montage

Guide tube

Max. guide tube length L

Version A

Version B

12 x 1 mm

660

3500

16 x 1 mm

1270

6000

17.2 x 1.6 mm

2100

6000

18 x 1.5 mm

3000

6000

Version A: Fixed to the tank ceiling

Version B: Fixed to the tank ceiling

and floor