8. Technical specifications

Temperatures, standard and pharmaceutical design

Tempera-

ture class

Maximum

process

temperature

Maximum ambient

temperature

(sensor head of

level sensor)

Dust maximum sur-

face temperature

(sensor head of level

sensor)

Category 1/2

T6

-60 ... 60 °C

-40 ... +40 °C

T≤ +95 °C

T5

-60 ... 80 °C

-40 ... +55 °C

T4

-60 ... 100 °C

-40 ... +85 °C

T3

-60 ... 150 °C

-40 ... +85 °C

T2

-60 ... 150 °C

-40 ... +85 °C

Category 2

T6

-60 ... 85 °C

-40 ... +40 °C

T5

-60 ... 100 °C

-40 ... +55 °C

T4

-60 ... 135 °C

-40 ... +85 °C

T3

-60 ... 200 °C

-40 ... +85 °C

T2

-60 ... 250 °C

-40 ... +85 °C

Nominal pressures

Process connection

Nominal pressure

Nom. pressure

Flanges

1) 2)

Triclamp connection

per DIN 32676

1) 3)

PN 6

6 bar

DN 10 - DN 50

0.5 inch - 2 inch

16 bar

PN 16

16 bar

DN 65 - DN 100

2.5 inch - 4 inch

10 bar

PN 40

25 bar

Dairy fitting

1)

PN 64

25 bar

DN 10 - DN 40

25 bar

150 lbs

15 bar (max. 148 °C)

DN 50 - DN 100

25 bar

300 lbs

25 bar (max. 148 °C)

DN 125 - DN 150

16 bar

600 lbs

25 bar (max. 148 °C)

Mounting thread G1 - G3

1)

These pressures can be applied on use

of suitabble:

1. Gaskets

2. Bolts

3. Tensioning rings

In cases of maximum bolt threading length and

suitable gaskets at the process connection, the

float pressure specification applies

Ingold-Stutzen

1)

DN 25

4 bar

If the pressure specifications for the process connection (e.g. flange) and float differ, the lowest