3 Operation

Determination of pump capacity, Pump Unit B

– Leave speed selector switch setting unchanged.
– Leave volume ratio setting of 1:1 unchanged.

Proceed analogously and in a mirror inverted manner, as described above for
Determination of pump capacity, Pump Unit A.

Determination of calibration factor

Example for calibration factor calculation:

X = amount of product A discharged 10 grams
Y = amount of product B discharged 11 grams

Fill measuring cup (30 – 50ml) one third full with water, dispense and read off

the amount discharged.

Formula: X/(Y:100) = calibration factor 10/(11:10) = 90.9 %

For the description how to enter the calibration factor go to Section 3.8.5.