75

3 Operation

3.8.5

Enter calibration factor

The capacity of pump B is calibrated to ensure accurate control and consistency of
Part A and Part B mixing ratios.

The capacity of pump A is the reference value (100%). For determination of the
calibration factor proceed as described in Section 3.4.

Enter calibration factor:

• With the dispensing station in ready state, push * button twice - display indicates

Enter password.

• Enter password, see Section 3.8.1.
• Push OK button three times - display indicates Calibration factor.

• Use arrow keys to enter desired value.

Arrow key assignment / setting range:
left: -10; right: +10; up: +1;
down: -1; setting range: 70 – 140.

• Push OK button to save the setting – display indicates "next menu item". Push

ESC key to leave the service menu – display indicates Operation.

3.8.6

Select User Interface language

Messages can be displayed in German or in English.

Interface language setup:

• With the dispensing station in ready state, push * button twice - display indicates

Enter password.

• Enter password, see Section 3.8.1.
• Push OK button 4 times - display indicates Language selection

or

The following languages can be
adjusted:

– Deutsch
– French
– Italian
– Portuguese

• Use arrow keys to enter desired value.
Arrow key assignment / setting range: left: German; right: English
• Push OK button to save the setting – display indicates "next menu item". Push

ESC key to leave the service menu – display indicates Operation.

Language

english

OK/ESC

Adjustment

105 %

OK/ESC