background image

79

4 Operator Menu Programming

4.3 Error

Messages

If this error message is displayed a new dispensing start cannot be released.
Pressing the DEL key after correction of error can reset fault signals. Only after this a
new start can be released.

Message: System error

The message indicates which pump unit (A or B)
was found to be in error.

Excess pressure

Pressure switch indicates pressure >40 bar

Container empty

Pump unit is in bottom position. Product container / receptacle
empty.

Motor

Pump motor not working properly.

Message: Range Exceedance Speed

Speed selector switch for pump capacity setting was set to a "wrong" range. The
allowable range for selector switch settings to be performed by the machine operator
is limited by product specific characteristics and by the Range Max. setting – see
Section 3.7.3. To correct the error, set speed selector switch to "correct" range and
reset fault signal by pressing the button DEL.

With exceeding of the MIN and/or MAX of range of the speed a change
of the mixing ratio is happened.

Minimum speed is factory set to approx. 2 rpm.

Wrong password

• Push ESC button twice to leave the menu, and enter correct password again.

Error DEL

Overpressure A B

Motor

A B

Pail empty A B

Error Range

MIN

DEL

MAX