3 Operation

3.8.4

Flush time (optional)

To prevent any undesired reaction of product components during idle periods, the
length of an automatic mixer flush cycle can be set provided that the system is
equipped with the optional dispense gun docking station. Setup of flush cycle time
intervals has been described in the previous menu item.

Flush time setup:

• With the dispensing station in ready state, push * button twice - display indicates

Enter password.

• Enter password, see Section 3.8.1.
• Push OK button twice - display indicates Flush time

• Use arrow keys to enter desired value.

Arrow key assignment / setting range:
left: -1; right: +1; up: +0.1;
down: -0.1; setting range: 0,1 – 20,0

• Push OK button to save the setting – display indicates "next menu item". Push

ESC key to leave the service menu – display indicates Operation.

Adjust flush time setting to make sure that flush volume is at least equal to mixer

volume.

Flushing Time

1.0 sec.

OK/ESC