3 operation – Henkel LOCTITE 97504 Benutzerhandbuch

Seite 70

Advertising
background image

70

3 Operation

3.7.5 Dispense

time

This menu item is only available if Timed mode has been selected.

When set to Time mode, the dispensing station delivers product during a pre-set
time span after the meter-mix dispense gun has been actuated. (for Operating mode
setup see previous menu).

Dispense time setup

• With the dispensing station in ready state, push OK button 4 times - display

indicates Operating mode..

• Push ALT button to go to Dispense time mode.

• Use arrow keys to enter desired value.

Arrow key assignment / setting range:
left: -1.0; right: +1.0; up: +0.1;
down: -0.1; setting range: 0.1 – 10.0

• Push OK button to save the setting – display indicates "next menu item". Push

ESC key to leave the operator menu – display indicates Operation.

Operational Mode

Cont. Mode

OK/ESC

*

Dosing Time

5.3 sec.

OK/ESC

*