3 operation – Henkel LOCTITE 97504 Benutzerhandbuch

Seite 72

Advertising
background image

72

3 Operation

3.8.1 Enter

password

The service menu is protected by password 3425.

Open service menu, enter password

• With the dispensing station in ready state, push * button twice - display indicates

Enter password.

• Enter password 3425 within 40 seconds using

the arrow keys, then push OK button - display
indicates Enter password

The password is entered right aligned. If the current position is shifted, the existing
numerical value is cleared and replaced by the * .

Arrow key assignment:
Left Shift current position to the left.
Right Shift current position to the right.
Up Increase input value by 1
Down Decrease input value by 1.

Connections to the two pump motors are not monitored via the service menu.

3.8.2 Retract

time

To prevent post-dispense dripping, product is sucked back into the meter-mix
dispense gun. Simultaneously, reversing the direction of pump rotation reduces
delivery pressure in the pressure lines.

Retract time setup:

• With the dispensing station in ready state, push * button twice - display indicates

Enter password.

• Enter password, see Section 3.8.1.

• Use arrow keys to enter desired value.

Arrow key assignment / setting range:
left: -1.0; right: +1.0; up: +0.1;
down: -0.1; setting range 0.0 – 1.0

• Push OK button to save the setting – display indicates "next menu item". Push

ESC key to leave the service menu – display indicates Operation.

The 0.3 value is a factory-recommended setting.

Suck Back Time

0.3 sec.

OK/ESC

PASSWORD:

0000

ESC

OK

Advertising