5 Maintenance

• Push motor bracket (D) upwards, and lightly hand tighten the locking screw (G).
• Hold pump unit and use screws (E) to secure it to the motor bracket. Hand tighten

the screws.

• Position Receptacle (N) underneath the Pump Unit, between the 3 centering pins.
• Hold Pump Unit and back off locking screw (G). Lower the pump unit slowly and

carefully until it rests against the receptacle.

• Lightly hand tighten the locking screw (G).
• Back off screws (E) and align the pump unit. When the wiper ring (S) is positioned

so that it is centered with respect to Receptacle (N), tighten screws (E).

• Connect plug connection (B) pump motor.
• Connect plug connection (A) pressure switch.
• Connect pressure line (H).

Dispensing station must be adjusted each time after stator
replacement, see Section 3.7.2.

Crush hazard: Risk of fingers getting crushed when pump unit is
lowered. Do not allow fingers to get between follower plate and
receptacle and/or product container.