5 Maintenance

5.3

Replacing Stator / Wiper Ring

Preparation

• Switch dispensing station off and safeguard against unauthorised use.
• Disconnect compressed air supply.
• Remove product container – see also Section 3.5.

5.3.1 Unscrew

pump

unit

• Raise Pump Unit (D) to top position (direction of arrow) and hold.
• Lightly hand tighten the locking screw (G). Pump unit is locked into place in top

position.

• Disconnect plug connection (A) pressure switch.
• Disconnect plug connection (B) pump motor.
• Unscrew pressure line (H).
• Hold pump unit and remove screws (E).