C) safe ilz, Logik / logic, Assembly and function – NORSTAT Safety Relays Benutzerhandbuch
Seite 145: Two-hand control relay for interbus inline system

application guide safety relays from riese electronic
page 141
c) SAFE ILZ
Two-hand control relay for Interbus Inline System
Assembly and function
S11, S12, S21, S22, Y1, Y2
Activation- and release contacts
51,
54
Auxiliary
contacts
UM-US, 13-14
Safety current circuit (normally open)
The activation and input contacts have to be wired according to the intended purpose (s. of " assembly
and line-up "). For the operation of the device, it must be connected with the Inline system. Over the Inline
bus terminal or a inline power terminal the voltage supply of 24V/DC is taken over. It lights up the LED
"UM".
For the start the terminals Y1 and Y2 have to be bridged (Feedback loop circuit control). The safety
device SAFE ILZ activates the safety current circuits only if the loop back circuit (Y1-Y2) is closed.
14
14
13
13
S11
S12
S21
S22
Y1
Y2
51
54
Logik / Logic
+7.5V (U
L
)
+24V (U
ANA
)
Local bus
+24 V (U
M
)
Local bus
+7.5V (U
L
)
+24V (U
ANA
)
+24 V (U
S
)
OPC
ELF
S1
S11
S12
S21
S22
Y1
Y2
13
14
Überwachung externer Schütze
Monitoring external contactors
51
54
S2