6 Expansion modules
Expansion modules are used to increase the number of safety outputs and can be connected to a normal
safety relay. The number of expansion modules connected to a safety relay should not exceed 6. There are
two possible versions available :
type
specialties
safety output
auxiliary outputs
opposite polarity
between channels
category
SAFE IL2
63 mm housing
5
1
-
4
SAFE X4 / 4.1
22,5 mm housing
4
1
selectable
4
NAGX 5
45 mm housing
5
1
selectable
4
SAFE IRZ.2
22,5 mm housing
1 changer
1
selectable
suitable up to risk
category max. 4
control dependent
SAFE IRZ.2 / RS – NAGX 5 : conversion of semiconductor output to relay output
(RS-NAGU, NAGU.1, RS- NAGU.1b, RS-NAGU.12)
Function diagram SAFE X4
A transformer is used for the following voltages:
48, 110-127, 230VAC.
A electrical fuse is used instead of an transformator with the 24VAC/DC voltage device.
Æ
some applications as well as expansions with contactors are shown on page 132.
elektr. Sicherung
Transformator /
electr. Fuse
transformer
Überwachungslogik /
-
AC
A1
K1
Y2
DC
+
K2
14
24
34
44
Y1
Controller Logic
A2
U1 U22
K1
K21
13
23
33
43
NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866