Safe z, C) safe z, D) rs-nagz – NORSTAT Safety Relays Benutzerhandbuch
Seite 81: Rs-nagz, Connection plan

application guide safety relays from riese electronic
page 77
T44
U ext
K2ext
.
X1
T11 T34
K1
ex
t.
S2
RS-NAGZ
T12
X2
T22
S1
24
42
41
14
13
24
23
K1ext.
K2ext.
13
14
S ext
23
c) SAFE Z
Connection plan
Two hand control relays SAFE Z according to
BG,
section iron and metal III ZH 1/456 (o2.78) and
DIN EN 574 (02.97) for type I - III c.
Suitable up to
category 4; SIL3; PLe reachable
Operate mode
There must be installed an auxiliary voltage at
the terminals A1 and A2 in order to operate the
device.
Then power LED starts illuminating. By pressing
the button S1 simultaneously to S2 the safety
outputs 13-14 and 23-24 will switch. This causes
an machine connected to the safety outputs gets
able to start.
Attention: The simultaneous of the two hand
control button S1 and S2 has to be smaller 0,5
sec.
If one or both buttons released, the outputs 13-1
simultaneous and 23-24 will open
immediately.Only after releasing S1 and S2 a
new cycles can be started. If the simultaneous
time will be bigger than 0,5 sec the outputs will
not be released. The outputs 13-14 and 23-24
stay open. The machine cannot be started.
It is possible to connect machine-release-circuits
at the terminals S21 and Y2.
The contact extension have to get export.
S11
SAFE Z
A2(-)
A1(+)
S1
S2
24V AC/DC
S21
S22
Y2
d) RS-NAGZ
Connection plan
Two hand control relays RS-NAGZ according to
BG, section iron and metal III ZH 1/456 (o2.78)
and DIN EN 574 (02.97) for type I - III b.
Suitable up to category 3; SIL2; PLd reachable
NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866
Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com