Cascading – NORSTAT Safety Relays Benutzerhandbuch
Seite 33

application guide safety relays from riese electronic
page 32
Cascading:
8k2
1'
2'
3'
4'
1'
2'
Several mats can be cascaded easily. The principle remains the same.
Remark:
Normally the switch between the two mat elements will not be drawn.
Specifications of possible riese safety relays for safety mats and safety contact edges
type
specialties
safety output
auxiliary
outputs
opposite
polarity
between
channels
category
SAFE M
22,5 mm
3
1
yes
3
SAFE 2.2*
22,5 mm
2
-
yes
4
SAFE IL1
Field bus connection
over Inline system
1+ 1
-
selectable
4
RS-NAGAO*
45mm housing
3
1 selectable
4
Relevant information:
*It must be guaranteed that the safety mat or safety contact edge - during load with a standard weight - does
not have a resistance more largely than 1
Ω.
NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866