9 safety combination / linkage, For example safe c, Block diagram features – NORSTAT Safety Relays Benutzerhandbuch
Seite 42: Cyclical self-monitoring by internal controllers, Wear free, short circuit proof auxiliary output, Up to 3a of load current, Alternatively single- or two-channel configuration, Monitoring of the reset circuit, Terminal(s) description of function

application guide safety relays from riese electronic
page 40
9 Safety combination / Linkage
for example SAFE C
Block diagram
Features:
Cyclical self-monitoring by internal controllers
Controllers supervise themselves independently by internal communication
Wear-free, short circuit proof safety semiconductor outputs (on-state: 24V DC, off-state: 0V DC)
Wear free, short circuit proof auxiliary output
Cyclic monitoring of the safety outputs by clocked operation
Opposite polarity between channels (only with two-channel configuration)
Up to 3A of load current
Alternatively single- or two-channel configuration
Monitoring of the reset circuit
Monitoring of complete plants by the linkage of several devices among themselves
AND – linkage between three SAFE C1 devices
AND – linkage between two SAFE C1 devices
A1 A2
Power
Input circuits
S12
S22
S34
S35
S32
Y1
Output
circuits
Combination
circuit
S11
S12
S33
MCU1
<Controller 1>
MCU2
<Controller 2>
Saf
et
y o
ut
pu
t circ
uit
s
14
24
34
42
Terminal(s)
Description of function
S11, S12, S21, S22
Activation- and release contacts
S32, S33
Combination circuit configuration
S34
Reset circuit input
S35 Operating
mode (1/2-channel)
14, 24, 34
Safety semicontactor outputs
42
Auxiliary output (PLC)
A
14
24
B
S33
S32
S11
24
14
K2
K3
K1
e-stop
safety gate
A
14
24
C
S33
S22
S12
24
14
K1
K2
14
24
B
S32
34
K3
A
14
24
C
S33
S22
S12
K1
K2
S32
e-stop
safety gate
NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866
Tel: 973-586-2500 Fax: 973-586-1590 www.norstat.com