1.3

Operating statuses of the vacuum module

The vacuum module can be in the following operating statuses:

Operating status

Solenoid coil 12

Solenoid coil 14

Explanation

Generate vacuum

Controlled

(via valve terminal)

Not controlled

Solenoid coil 12:

impulse control with lock

1)

Generate vacuum

Not controlled

Not controlled

Operating status after failure of

the pilot air supply or the

electrical supply of the vacuum

module

Tab. 2

Air saving

Controlled

(via internal

electronics of the

vacuum module)

Controlled

(via internal

electronics of the

vacuum module)

Maintain vacuum in valve

mid-position

1)

Ejection

Not controlled

Controlled

(via valve terminal)

Vacuum accelerates

dismantling

1)

Normal position

2)

Not controlled

Not controlled

Status after the end of the

“Ejection” signal

1)

1)

Also see

Fig. 3 and Fig. 4

2)

Normal position means the vacuum module is

not in the “Generate vacuum”, “Air saving” or “Ejection” operating status.

Tab. 1

Operating statuses of the vacuum module

If the pilot air supply or the electrical supply of the vacuum module is switched off, the respective oper-

ating status is changed as follows (

Tab. 2).