VABF-S4-1-V2B1…

Festo – VABF-S4-1-V2B1…-D2 – 1212a English

59

Actuating the manual override with stop (detenting actuation)

Use a screwdriver to press down the plunger of the manual

override as far as possible. Then turn the plunger 90° in a

clockwise direction.

The valve reverts to the switching position and remains

switched.

Then turn the plunger 90° in an anti-clockwise direction.

Then release the plunger.

The valve reverts to the rest position.

Tab. 7

Manual override, detenting

7.2

Changing settings and values

Information such as settings and values can be changed,

section 6.3 “EDIT mode”.

Note

The last saved settings are retained in the event of a power failure.