2 show mode, 1 display settings for out a/b – Festo Рабочие компоненты для VTIA, ISO 15407-2 Benutzerhandbuch

Seite 54

Advertising
background image

VABF-S4-1-V2B1…

54

Festo – VABF-S4-1-V2B1…-D2 – 1212a English

Symbol

Description

Marked segments illuminate:

SHOW mode active

Diagnosis: 7-segment display shows error number (e.g. Er01)

Marked segments illuminate and [Option] flashes:

EDIT mode active

Special menu (SPEC) is open, 7-segment display shows the set filter option

Marked segments illuminate and [Lock] flashes:

EDIT mode active

Special menu (SPEC) is open, 7-segment display shows the security code

Tab. 5

Special symbols of the segment bars

6.2

SHOW mode

The following settings and values are indicated in the SHOW mode:

Settings for Out A/B

Switching function [threshold/window comparator]

Switching points [SP] or [SP] [min] and [SP] [max]

Hysteresis [HY]

Switching characteristic [NO/NC]

Extreme values of input values

Minimum pressure value [min]

In order to delete the minimum value, press the EDIT button briefly.

Maximum pressure value [max]

In order to delete the maximum value, press the EDIT button briefly.

6.2.1

Display settings for Out A/B

The vacuum module must be in the RUN mode.

Press the A-button (switching output Out A) or the B-button (switching output Out B).

The SHOW mode of the corresponding switching output is active.

Press the button of the selected switching output again.

If you continue pressing the button, the current settings of that switching output will be dis-

played one after the other as the button is pressed.

If all values have been displayed and the button is pressed again, the RUN mode is reactivated.

The “Show mode” menu structure can be found in section 13.