Festo Рабочие компоненты для VTIA, ISO 15407-2 Benutzerhandbuch

Seite 62

Advertising
background image

VABF-S4-1-V2B1…

62

Festo – VABF-S4-1-V2B1…-D2 – 1212a English

Malfunction

Remedy

Possible cause

Required vacuum is

not obtained

Insufficient supply of air to the valve

terminal

Increase supply pressure

Increase supply cross section

Install an additional supply plate

directly next to the vacuum

module, optionally create a

separate pressure zone, see

manual VTSA/VTSA-F

Soft-start valve installed on the valve

terminal

If the valve terminal is pressurised,

first send an electrical release

signal (14) to deactivate vacuum

generation. Only revert to vacuum

generation after full operating

pressure of the valve terminal has

built up (12).

Vacuum module does

not revert to the

air-saving function

Insufficient supply of air to the valve

terminal

Increase supply pressure

Increase supply cross section

Install an additional supply plate

directly next to the vacuum

module, optionally create a

separate pressure zone, see

manual VTSA/VTSA-F.

Switching thresholds or hysteresis

set incorrectly

Correct switching thresholds and/or

hysteresis

Channel A and/or B set as N/C

contact (NC)

Set channel A and B as N/O contact

(NO)

Channel A and/or B set as window

comparator

Set channel A and B as threshold

value comparator

Er01

1)

Pressure sensor defective

Send device to Festo

Er09

1)

Value below measuring range

with In A

Maintain permitted measuring range.

If the permitted maximum values are

exceeded, the pressure sensor must

be replaced. Send device to Festo.

Er10

1)

Measuring range exceeded

with In A

Er11

1)

Value below measuring range with

In B

Er12

1)

Measuring range exceeded

with In B

Er17

2)3)

Undervoltage

Maintain operating voltage

1)

7-segment display flashes. Error display in the SHOW mode (

section 6.2 “SHOW mode”).

2)

7-segment display flashes. The smallest current error number is shown.

3)

Outputs are reset automatically (0-signal).

Tab. 8

Troubleshooting

Advertising