1 symbolic lcd display – Festo Рабочие компоненты для VTIA, ISO 15407-2 Benutzerhandbuch

Seite 53

Advertising
background image

VABF-S4-1-V2B1…

Festo – VABF-S4-1-V2B1…-D2 – 1212a English

53

6.1

Symbolic LCD display

Display

Symbol

Description

Mode

RU

N

SH

O

W

ED

IT

TE

AC

H

Switching output set/not set

X

Switching output selected/not selected

X X X

Threshold value comparator

X X

Window comparator

X X

[SP]

Switching point

X X

[SP] [min]

Lower switching point
(switching point – minimum)

X X

[SP] [max]

Upper switching point
(switching point – maximum)

X X

[HY]

Hysteresis

X X

[NO]

Switching characteristic of
normally open contact

X X

[NC]

Switching characteristic of
normally closed contact

X X

[min] / [max]

Extreme values: Minimum/maximum input
measured value (In A1)

1)

X

[TeachIn]

TeachIn mode active

X

[Lock]

Security code active
(blocking of unauthorised parameterisation)

X

X

Special menu (SPEC) is active

1)

X

RUN mode: Graphic display of the current
measured value related to the maximum
measured value of the measuring range. The
left-hand segment row shows the measured
value of In A, the right-hand segment row
shows the measured value of In B.

Meaning in other modes:

Tab. 5

X

1)

The segment bars also show special symbols

Tab. 5

Tab. 4

Symbols on the display

Besides the graphic display of the current measured value the segment bars also indicate different

states of the pressure switch via defined symbols.