Fig. 4 illustrates the operating mode of the air-saving circuit. The pressure curve together with the

threshold values and thresholds is illustrated in the upper part of the diagram. The corresponding con-

trol input signals of the valve terminal, the output signals of the pressure sensor and the LED switching

status displays of the solenoid valve are shown at the bottom of the diagram.

Hysteresis

Vacuum

0

Excess pressure

1

2
3

4

Valve terminal

inputs

LED display

on valve

Pressure

sensor outputs

1 Threshold value channel A “switch off

suction” (air-saving function)

2 Threshold value channel A “switch on

suction”

3 Switching point channel B “vacuum query”
4 Ejector pulse

Fig. 4

Operating mode of the air-saving function

Vacuum generation is switched off when the vacuum is higher than threshold

1 and is switched on

again when the vacuum is less than threshold

2.