Festo – VABF-S4-1-V2B1…-D2 – 1212a English

49

4.2

Pneumatic

Connect the QS push-in fittings with appropriate tubing.

Recommendation: Use PUN-10 tubes from Festo (ID code “QS-large” in the Festo Configurator).

4.3

Electrical

Warning

Use only power sources which guarantee reliable electrical isolation of the operating
voltage in accordance with IEC/EN 60204-1. Consider also the general requirements
for PELV circuits in accordance with IEC/EN 60204-1.

Note

Long signal lines reduce the resistance to interference.

Make sure that the signal cables are not longer than 5 m.

Note

Electrical components may become damaged if the maximum permitted voltage is

exceeded.

Make sure that the operating voltage supply is DC 24 V ± 10 %.

Connect the cable socket to connection

2. ( Fig. 1 “Operating elements and ports”)

Wire the vacuum module as illustrated in Tab. 3.

Connector

2)

4-pin M12

(Top view of the vacuum

module connector)

Pin

Cable colours

1)

Assignment

1

Brown (BN)

Supply voltage DC +24 V

2

White (WH)

Switching output B (Out B)

3

Blue (BU)

DC 0 V

4

Black (BK)

Switching output A (Out A)

1)

Using the connector socket with cable as per “Accessories”.

2)

Max. tightening torque 0.5 Nm.

Tab. 3

Pin assignment