12 technical data – Festo Рабочие компоненты для VTIA, ISO 15407-2 Benutzerhandbuch

Seite 64

Advertising
background image

VABF-S4-1-V2B1…

64

Festo – VABF-S4-1-V2B1…-D2 – 1212a English

12

Technical data

Type

VABF-S4-1-V2B1-C-VH-20

Operating pressure

[bar]

4 … 8

Operating medium

Compressed air to ISO 8573-1:2010 [7:4:4]

Operation with lubricated medium not possible

Ambient temperature

[°C]

0 … 50

Temperature of medium

[°C]

0 … 50

Length/width/height

(with assembled silencers)

[mm]

285/53/88

Operating voltage range

[DC V]

24 ± 10 %

Coil characteristics DC 24 V

[W]

1,3

Idle current

[mA]

50 … 150

(dependent on the switching status of the

solenoid coils)

Ready-state delay

[ms]

< 500

Switching outputs

– Max. output current

[mA]

50

– Voltage drop

[V]

≤ 1.5

– Capacitive load max. DC

[nF]

≤ 100

Protective functions

– Inductive protective circuit

Adapted to MZ, MY, ME coils

– Protection against short circuit

Yes

– Protection against overloading

Yes

Reverse polarity protection

For all electrical connections

Protection class

IP65

Interference immunity

See declaration of conformity (www.festo.com)

Interference emission

See declaration of conformity (www.festo.com)

Max. permitted signal line length

[m]

5

Overload pressure at vacuum

connection

[bar]

≤ 5

Pressure measuring range

[bar]

–1 … 0

Accuracy

[% FS]

±3

Threshold value setting range

[bar]

–0.999 … 0

(recommended operating range: –0.95 … –0.05)

Hysteresis

[% FS]

±0.1

Setting range for hysteresis

[bar]

–0.9 … 0

Tab. 10

Technical data

Advertising