5 quick commissioning with default settings, 5quick commissioning with default settings – Festo Рабочие компоненты для VTIA, ISO 15407-2 Benutzerhandbuch

Seite 50

Advertising
background image

VABF-S4-1-V2B1…

50

Festo – VABF-S4-1-V2B1…-D2 – 1212a English

5

Quick commissioning with default settings

The pressure switch of the vacuum module has the following settings when delivered:

Channel A, air-saving function

Switching characteristics:

Threshold value comparator

Switching point

–700 mbar

Hysteresis:

200 mbar

Switching characteristic:

NO (normally open contact)

Channel B, vacuum query

Switching characteristics:

Threshold value comparator

Switching point

–400 mbar

Hysteresis:

5 mbar

Switching characteristic:

NO (normally open contact)

If you do not want to use these settings, you can set a switching point for Out A or Out B manually

(

section 6.3.2).

Advertising