Gb 9. maintenance, accessories, Trouble shooting – WIKA D-11-9 Benutzerhandbuch
Seite 12
2450786.06 GB/D 10/2010
22 WIKA Operating instructions/Betriebsanleitung D-10-9, D-11-9
2450786.06 GB/D 10/2010
23
WIKA Operating instructions/Betriebsanleitung D-10-9, D-11-9
ID
DLC
Byte 0
Byte 1
Byte 2
7E5h
8
15h
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Baud Rate
Index table
1000 kBit
0
800 kBit
1
500 kBit
2
250 kBit
3
125 kBit
4
100 kBit
5
50 kBit
6
20 kBit
7
10 kBit
8
ID
DLC
Byte 0
Byte 1
Byte 2
7E5h
8
04h
00h
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Error
Cause
Recovery action
The setting of the node-ID has been
confirmed as successful, but it is not active.
Settings are taken over
by the DIP-switch.
Change over DIP-switch so that the parameters
from the device-internal memory are loaded.
The setting of the data transfer rate has
been confirmed as successful, but it is not
active.
Settings are taken over
by the DIP-switch.
Change over DIP-switch so that the parameters
from the device-internal memory are loaded.
8. Communication (LSS-Services according to CiA 305 V1.0)
GB
Byte 1-2 Switch Delay (time in ms, which is to pass until the new Baud rate is activated).
Activate bit timing by
Bit timing table
Change from configuration mode to operation mode via switch mode global:
9. Maintenance, accessories / 10. Trouble shooting
GB
9. Maintenance, accessories
Accessories: For details about the accessories (e. g. connectors), please refer to WIKA‘s
price list, WIKA‘s product catalog on CD or or contact our sales department.
WIKA pressure transmitters require no maintenance.
Have repairs performed by the manufacturer only.
10. Trouble shooting
Open pressure connections only after the system is without pressure!
Do not insert any pointed or hard objects into the pressure port for cleaning to prevent
damage to the diaphragm of the pressure connection.
Take precautions with regard to remaining media in removed pressure trans-
mitters. Remaining media in the pressure port may be hazardous or
toxic!
Remove the pressure transmitter from service and mark it to prevent it from
being used again accidentally, if it becomes damaged or unsafe for opera-
tion.
Have repairs performed by the manufacturer only.
Warning
!
Warning