Specifications
Model D-10-9 / D-11-9
Pressure ranges
bar
0.25
0.4
0.6
1
1.6
2.5
4
6
10
16
Over pressure safety
bar
2
2
4
5
10
10
17
35
35
80
Pressure ranges
bar
2.4
2.4
4.8
6
12
12
20.5
42
42
96
Messbereich
bar
25
40
60
100
160
250
400
600
1000
1)
Over pressure safety
bar
50
80
120
200
320
500
800
1200 1500
Burst pressure
bar
96
400
800
800
1000 1200 1700
2)
2400
2)
3000
{Vacuum, gauge pressure, compound range, absolute pressure are available}
1)
Only Model D-10-9.
2)
For model D-11-9: the value specified in the table applies only when sealing is
realised with the sealing ring underneath the hex. Otherwise max. 1500 bar applies.
Materials
Wetted parts
(Other materials see WIKA diaphragm seal program)
»
Model D-10-9
*)
Stainless steel (pressure ranges > 25 bar additional Elgiloy
®
)
»
Model D-11-9
Stainless steel
{Hastelloy}
O-ring: NBR {FPM/FKM or EPDM}
Case
Stainless steel
Specifications
Model D-10-9 / D-11-9
Internal transmission fluid
3)
Synthetic oil {Halocarbon oil for oxygen applications}
{Listed by FDA for Food and Beverage}
3)
Not for D-10-9 with pressure ranges > 25 bar.
Power supply U
B
DC V
10
... 30
Signal output
CANopen Protokoll gemäß CiA DS-301 V. 4.02, Geräteprofil DS-404
V. 1.2
Power consumption
W
≤ 0.7
Communication services
LSS (CiA DSP 305, Version 1.1.1) Services
Configuration of device address and baud rate
Sync/Async, Node/Lifeguarding
Diagnosis data
Emergency Message, if pressure is 5% below minimum of measuring
range
or pressure is 5% beyond maximum of measuring range
or temperature at sensor is higher than 80 °C (176 °F)
Termination
Ω
Internal termination can be activated via integrated DIP-switch
Internal measuring rate
Hz
≤
100
Warm-up time
min
< 10
Insulation voltage
DC V
500
Accuracy
4)
% of span
≤
0.2 {0.10} in the range 0 ... +50 °C / +32 ... +122 °F
4)
Including non-linearity, hysteresis, zero point and full scale error (corresponds to
error of measurement per IEC 61298-2).
Adjusted in vertical mounting position with lower pressure connection.
Non-linearity
% of span
≤
0.04 (BFSL) according to IEC 61298-2
1-year stability
% of span
≤
0.10
(at reference conditions)
Permissible temperature of
Medium *
)
-20 ... +80 °C
-4 ... +176 °F
Ambience
-20 ... +80 °C
-4 ... +176 °F
Storage
-40 ... +85 °C
-40 ... +185 °F
Compensated temp range
-20 ... +80 °C
-4 ... +176 °F
PIN assignment of connections according to CiA-DR 303-1
1 – Screen
2 – UB+ (CAN V+)
3 – UB- (CAN GND)
4 – Bus-Signal CAN-High
5 – Bus-Signal CAN-Low
7. Starting, operation
GB
The technical specifications given in the data sheet are only accurate after a warming up
period of approx. 10 minutes.
7. Starting, operation
GB
Circular connector M 12x1, 5-pins, IP 65, Order code: M5