Specifications

Models WUD-20, WUD-25 and WUD-26

WUD-20, WUD-25

WUD-26

Pressure ranges

psi

15

30

60

100

160

250

350

500

1,000

1,500

bar

1

2

4

7

11

17

25

36

70

100

Over pressure safety

1)

psi

120

120

120

210

320

500

750

1,100

2,100

3,000

Burst pressure

1)

psi

1,800

1,800

1,800

2,200

2,600

4,800

6,200

7,400

8,000

10,500

Pressure ranges

psi

2,000

3,000

5,000

bar

145

225

360

Over pressure safety

1)

psi

4,200

6,600

10,000

Burst pressure

1)

psi

10,500 10,500 10,500

Other pressure ranges, pressure units (e.g. MPa, kg/cm

2

) on request

Absolute pressure: 0...2 bar to 0...60 bar, Vacuum pressure: -1...1 bar to -1...250 bar

Measuring principle

Metal thin-film sensor

Materials

Wetted parts
- Pressure connection

316L VIM/VAR

- Pressure sensor

2.4711 / UNSR 30003

Case
- Lower body

304 SS

- Plastic components

PBT

- Keyboard

TPE

- Display cap

PC

Particle test

≤ 0.1 µm Particle 0.1 ptc / ft

3

according to Semi E49.8

Inboard helium leak test

< 1 x 10

-9

mbar l/sec (atm STD cc/sec) according to Semi F1

Surface finish

Electropolished, typical Ra ≤ 0.13 µm (RA 5); max. Ra ≤ 0.18 µm (RA 7) according to Semi F19

Dead volume

WUD-20 < 1.5 cm

3

, WUD-25 < 1 cm

3

, WUD-26 < 1 cm

3

Permissible medium

Special gas, vapour, liquid

1) 1 psi = 0.069 bar

7. Initial start-up and operation

GB

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: