Initial start-up and operation, Operating instructions/betriebsanleitung, wud-2x – WIKA WUD-26 Benutzerhandbuch
Seite 13

11611057.01 GB/D 11/2013
13
Operating instructions/Betriebsanleitung, WUD-2x
Specifications
Models WUD-20, WUD-25 and WUD-26
Permissible temperature of
■
Medium
-20 ... +100 °C / -4 ... +212 °F
■
Ambience
-10 ... +60 °C / 14 ... 140 °F
■
Storage
-10 ... +60 °C / 14 ... 140 °F
Rated temperature range
-20 ... +80 °C / -4 ... +176 °F (active compensated)
Temperature coefficients within
rated temperature range
(active compensated)
■
Mean TC of zero
≤
0.10 % of span / 10 K
■
Mean TC of range
≤
0.15 % of span / 10 K
RoHS-conformity
Yes
CE- conformitiy
■
Pressure equipment directive
97/23/EC
■
EMC directive
2004/108/EC, EN 61326 Emission (Group 1, Class B) and Immunity (industrial locations)
Assembly and packing area
Clean room class 5 according to ISO 14644
Packaging
Double bagging according to SEMI E49.6
Shock resistance
15 g (11 ms); 30 g (6 ms)
Vibration resistane
7.5 mm or 2 g (1 ... 200 Hz) / 5 g
Wiring protection
■
Short-circuit proofness
S
+
towards U-
■
Reverse polarity protection
U
+
towards U-
Weight
Approx. 0.2 kg
7. Initial start-up and operation
When designing your plant, take into account that the stated values (e.g.burst pressure, over pressure safety)
apply depending on the material, thread and sealing element used.
GB