Operating instructions/Betriebsanleitung, WUD-2x
Menu (programming and factory setting)
Operating mode
Long press on down key
Programming mode
Factory setting:
SP1
Value
(Min: MBA +0.5 %
Max: MBE)
60 % of instrument nominal pressure
RP1
Value
(Min: MBA
Max: SP1 -0.5 %)
40 % of instrument nominal pressure
SP2
1)
Value
(Min: MBA +0.5 %
Max: MBE)
60 % of instrument nominal pressure
RP2
1)
Value
(Min: MBA
Max: SP2 -0.5 %)
40 % of instrument nominal pressure
EF
RES
Yes / No
Reset to factory setting
DS1
Value
0 ... 50 s
0 s
DR1
Value
0 ... 50 s
0 s
DS2
1)
Value
0 ... 50 s
0 s
DR2
1)
Value
0 ... 50 s
0 s
OU1
PARA
OFF, ON, NO, NC
NO
OU2
1)
PARA
OFF, ON, NO, NC
NO
DISU
Value
0.2, 0.5, 1, 5, 10, 60 seconds
0.2 s
DISO
Value
(± 10 % of full scale)
0%
Legend:
MBA = Start of measuring range
MBE = End of measuring range
1) Only available for instruments with two switching outputs
END
END
Operating mode
7. Initial start-up and operation
The switch returns to the operating mode, if no key is pressed within 1 minute.
GB