4. Design and function

Reservoir

Valve A

Hand pump

Valve B

4.4 Function

Operation of the comparison test pump is controlled by the two valves A and B on

the top of the reservoir/high pressure cylinder block. When initially priming the system

valves A and B are opened to fill the system with oil from the reservoir. Valve B is then

closed with valve A left open and the spindle pump operated to provide the lower test

pressures. To provide the higher pressures valve A is closed to seal off the test circuit

from the low pressure part of the spindle pump and valve B is opened to allow the liquid

in the low pressure part of the spindle pump to return to the reservoir as the pump

is operated. This ensures that the pump can be operated without having to put large

forces on the spindle pump handwheel. To release the test pressure the spindle pump is

wound out and valve A is opened.