1 character set – EUCHNER HBAS 094594 Benutzerhandbuch

Seite 64

Advertising
background image

EUCHNER

Hand-Held Pendant Station

HBAS-094594

095640-02-02/06

Subject to technical modifications

Page 24 / 40

Example: Status request and sending key S11 and error byte 31H

HBAS

DLE

DLE STX

3BH

31H

DLE ETX

BCC

Control
system

STX

23H

DLE

ETX

BCC

DLE

DLE

Error bytes

If an incorrect parameter is transferred for a command that requires a parameter, this error
byte can be polled by polling the status. The error byte is sent after the key information.

The following error messages are possible:

Error

byte

Error

Explanation

31H

No error

Error-free operating state

32H

Text not defined

An item of text opened with a short command

has not yet been defined

33H

Area not defined

An area opened with a short command has

not yet been defined

34H

Parameter invalid

A parameter entered is outside the valid value

range

35H

Too many parameters

The number of the parameters given does

not correspond to the number expected

36H

Area invalid

An area opened overlaps with a character that

is displayed with the large font. (Section 10.2.6)

9.2 Configuration parameter transfer (command byte 53H)

All parameters that can be set on the Configuration (Konfiguration) menu can be
transferred from the control system at any time.
For this purpose the command byte 53H must be set before the parameter data.

After the data transfer has been started, the STATUS LED goes out.
The display is cleared and the text "Save param." ("Par. speichern") output.

A short sound is emitted by the HBAS as an acknowledgement of the correct storage
of the data in the flash and the text "Save param." ("Par. speichern") is cleared.

If a parameter is not given correctly, then the error byte "34H" is set. The error byte can
be polled by the control system by polling the status.

Control system

requests status

HBAS sends key

and error byte