Page 35 / 40

10.3 Overview of commands

Identifier

byte

Command

byte

Description

Parameter:

21H

Cursor to the next character

22H

Cursor to the previous character

23H

Cursor one line down

24H

Cursor one line up

25H

Cursor at the start of the display

26H

Cursor at the start of the line

27H

Cursor at a specific position

Line, column

28H

Clear the current cursor position

29H

Clear to the end of the line

2AH

Clear to the end of the display

2BH

Clear the entire display

2CH

Clear a screen area

Start line, start column,
end line, end column

40H

Inverse on: all subsequent characters
are output inverse

41H

Inverse off

42H

Flashing on: all subsequent characters
are output flashing

43H

Flashing off

08H

Definition of an item of text

Text number,

font size, line,

column, text

49H

Output of a previously defined item of text

Text number

4AH

Definition of an area

Area number, start line, start
column, end line, end column

4BH

Clear a previously defined area

Area number

4CH

Inverse display of an area

Area number

4DH

Flashing display of an area

Area number

4EH

Inv. + flashing display of an area

Area number

4FH

Normal display of an area

Area number

50H
51H

Selection "small font"
Selection "large font"

6CH

80H ... FFH ASCII character set

23H

Status poll (keys 30H ... 44H and
error byte 31H ... 36H are sent)

52H

Continuous sound on
Continuous sound off
Pulsed sound on
Pulsed sound 0.5 s

30H
31H
32H
33H

none

53H

Transfer parameter settings

PIN, priority,

pulse generator active,

pulse generator delay,

key assignment,

pulse generator frequency,

key click