11. Installation instructions

The observance of the EMC regulations stipulated for the EUCHNER hand-held pendant
stations requires the use of screened connection cables.
The screen on the hand-held pendant station cable is connected to the plug housing.
A metal flange socket is to be fitted to the customer's installation and its housing grounded
with a low resistance and low inductance connection.
Further cables from this point to the communication interface and for the further processing
of pulse generator signals are also to be screened and the screen connected to a suitable
point of grounding on the control system.
A flange socket is available as an accessory for installation

An RS 422A transmitter module and an RS 422A receiver module are to be provided for
the communication interface.
An RS422A receiver module is to be provided on the control system for the pulse generator
signals.

12. Technical Data: Pulse generator

Pulse generator
Output circuit

RS 422A

Connection

A corresponding RS 422 receiver module is
to be used at the control system end

Pulse diagram for increasing numbers,
CW (clockwise rotation)

90˚

360˚

A

A

B

B

Idle condition

Pulse diagram for decreasing numbers,
CCW (counter clockwise rotation)

90˚

360˚

A

A

B

B

Idle condition

Driver layout

RS422

A

A

RS422

Transmitter

in the HBAS

Receiver

in the control system

RS422

B

B

RS422

Advertising