6 area commands, Hner e, Hner – EUCHNER HBAS 094594 Benutzerhandbuch
Seite 73

EUCHNER
Hand-Held Pendant Station
HBAS-094594
095640-02-02/06
Subject to technical modifications
Page 33 / 40
10.2.6 Area commands
The user can define up to 32 areas that can be cleared, inverted, displayed flashing
or normally using short commands. The otherwise valid attribute is not changed.
Command
byte
Description
Parameter:
4AH
Definition of an area
Area number
(
31H...51H
),
Start line
(
30H...37H
),
Start column
(
30H...3FH
),
End line
(
30H...37H
),
End column
(
30H...3FH
)
4BH
Clear a previously defined area
Area number
(
31H...51H
)
4CH
Inverse display of an area
Area number
(
31H...51H
)
4DH
Flashing display of an area
Area number
(
31H...51H
)
4EH
Inv. + flashing display of an area
Area number
(
31H...51H
)
4FH
Normal display of an area
Area number
(
31H...51H
)
Important: The line and column information is independent of the font size!
The area numbers are from 31H (area 1) to 51H (area 32).
If an undefined area is addressed, then the error byte is set to 33H.
The error byte can be polled using the status poll and is reset after the poll to 31H
(section 9.1).
Warning:
When a defined area is opened, there must not be any intersection between the area
boundaries and the boundaries of character in large font. If this is the case, the command
is not executed and the error byte is set to 36H. The error byte can be polled using the
status poll and is reset after the poll to 31H.
Example
E
U
C
HNER
E
U
C
HNER
Correct!
Incorrect!
Large font
Area:
31H, 31H, 32H, 3EH
(line 1 to 2 and
line 1 to 14)