4 - 1 0

CHARACTERISTICS PM 5414 V

4.8

Y/C & RGB UNIT

OUTPUT signals

1.

RED/GREEN/BLUE

impedance

75 Q

voltage (pp)

- 625 line systems

0.7 ±0.05 V

- 525 line systems

0.714 ±0.05 V

black level lift

0.054 ± 0.006 V

(setup)

DC blanking level

0.5 to 0.85 V

BNC connectors (rear panel)

into 75 Q

ampl. blanking level - 100 % white

for 525 line systems

All test patterns are available,

but there are two remarks :

DEM signals

- PAL/NTSC

VCR signals

only luminance part is fed out

bar 3, saturation steps:

only luminance part is presented

2.

PAL/NTSC SUBCARRIER

impedance

75 Q

voltage (pp)

1 ±0.15 V

BNC connector

into 75 Q

3. Composite SYNC

impedance

voltage (pp)

polarity, level

75 £2

2 ±0.3 V

negative going

BNC connector (rear panel)

into 75 Q

related to 0 V

4. SYNC in GREEN

TV systems

sync level

selection

-

Sync in Green

-

no Sync in Green

625 line

systems

-43% ±3%

525 line

system

-40% ±3%

100% = black to white

internal by jumper on pcb