8.2.2

Fault code

Note

There are of course faults with which the diagnosis no longer functions. Please refer to

the chapter Eliminating faults" for further information.

DiagĆ

nostic

stage

Fault

code

Description

Remedy

1

1)

Er34

Evacuation time exceeded in 2 of 5 cycles

Check for leakage

Er36

Pressurization time exceeded in 2 of 5 cycles

Check for leakage

2

2)

Er33

Solenoid valve does not switch or not

correctly.

Plunger does not move, current through

solenoid coil not sufficient, short circuit in

solenoid coil

Press mechanical manual

override several times.

Check supply voltage. If there is

no improvement, the device is

defective.

Send device to Festo.

Er35

The set threshold of the evacuation time is

exceeded double the value in 2 of 5 cycles

Check for leakage

Er37

The set threshold of the pressurization time

is exceeded double the value in 2 of 5 cycles

Check for leakage

Er38

Switching frequency of the air−save function

lies over the limit value 1 Hz

Check for leakage

Possible fault when switching on the

air−save function, switching point not logical

Reset input

3

3)

Er17

4)

Undervoltage in power supply < 15 V

Check the power supply

3

Er01

Device defective

Exchange device

ć

Er02

Ū

Er08

Reserved for extensions

ć

Er13

Ū

Er16

Reserved for extensions

ć

1)

[min] [max] flash synchronously; fault display in SHOW mode (è Tab. 11: )

2)

All segments flash. The smallest current fault number is shown.

3)

Centre row of bar code segments flashes; fault display in SHOW mode (è Tab. 11: )

4)

Outputs are reset automatically (0−signal).

Tab. 15: Fault code of the vacuum generator