OVEM

76

Festo ć OVEM ć 1004b English

5

Fast commissioning with factory setting

The vacuum generator is available with the following factory setting:

· Air−save function on the −CE/−OE: active

· Switching behaviour of the electrical output: Threshold value comparator

· Switching element function of the electrical output: NO (normally open Ĉ contact)

OVEM−

Ū−H−Ū

OVEM−

Ū−L−Ū

Out A

SP

−0.7 bar

−0.4 bar

SP

min

−0.7 bar

−0.4 bar

SP

max

−0.97 bar

−0.67 bar

HYS

0.25 bar

0.25 bar

0.25 bar

0.25 bar

SP

LS

−0.7 bar

−0.7 bar

−0.4 bar

−0.4 bar

HYS

LS

0.25 bar

0.25 bar

0.25 bar

0.25 bar

Out B

SP

−0.5 bar

−0.2 bar

SP

min

−0.5 bar

−0.2 bar

SP

max

−0.71 bar

−0.41 bar

HYS

0.2 bar

0.2 bar

0.2 bar

0.2 bar

Ejector pulse

200 ms

200 ms

200 ms

200 ms

Tab. 10: Factory setting

If you do not wish to use the factory setting, you can define a switching point for Out A or Out B as

follows. Switching points can be set manually or taught.

Note

The EDIT button is often used during commissioning to select and confirm values. To

avoid damage to the EDIT button, please actuate it only with a dull object.

1. Switch on the operating voltage.

è

The vacuum generator is then in the RUN mode (basic setting).

Note

If you are not sure whether the vacuum generator is in the RUN mode, hold the EDIT

button pressed down for 3 s. The vacuum generator returns to the RUN mode.