Festo Генератор вакуума OVEM, дюймовый Benutzerhandbuch

Seite 99

Advertising
background image

OVEM

Festo ć OVEM ć 1004b English

99

L

L

L

L

Fig. 22: Set diagnostic message channel di x (menu structure EDIT mode è Fig. 24: )

1. Press the EDIT button.

è

The EDIT mode is active and [Out A] flashes or flashes when security lock is active [Lock].

2. Press the UP/DOWN button until the desired security code is set.

3. Press the EDIT button.

è

[Out A] flashes.

4. Press the B−button (DOWN button).

è

[Out B] flashes.

5. Press the EDIT button in order to confirm the selection.

è

In A1 is displayed.

6. Press the B−button until the desired diagnostic mesage channel is selected.

7. Press the EDIT button in order to confirm the selection.

è

[NO] or [NC] flashes.

8. Set the switching characteristic [NO/NC] with the UP/DOWN button.

9. Press the EDIT button in order to confirm the selection.

è

The vacuum generator is in the RUN mode.

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: