OVEM

68

Festo ć OVEM ć 1004b English

Hysteresis

1 / 2

3
4

50 mbar (fix)

5

1

Threshold value Switch off suction"

2

Switch−on threshold Switch on message"

3

Threshold value Switch on suction" (internal)

4

Reset threshold Object gripped" (minimum)

5

Switch on suction" (external)

Fig. 5: Method of operation of the air−save function

With active air−save function:

Vacuum generation is switched off as soon as the vacuum is more than the threshold value

1 and is

switched on again as soon as the vacuum is less than the threshold value

3.

The threshold values are defined as follows:

Threshold value Switch off suction"

1

Threshold value

1 is equal to the switch−on threshold value 2 of the output Out A (è Fig. 5: ) set by

the customer, i.e. the vacuum generator is switched off when the output Out A is set.

Threshold value Switch off suction"

3

Threshold value

3 lies between the switch−on threshold 2 and the reset threshold 4 (switch−on

threshold minus the adjustable hysteresis) of the output Out A at a gap of 50 mbar from the reset

threshold. This is to prevent the reset threshold from being reached.