Festo Генератор вакуума OVEM, дюймовый Benutzerhandbuch

Seite 79

Advertising
background image

OVEM

Festo ć OVEM ć 1004b English

79

The vacuum generator need not be in the basic mode (RUN mode).

· Define the desired switching reaction of the switch outputs (è chapter 6.3 EDIT mode).

The work item must be held reliably against the suction gripper by the vacuum generated.

The intensity and duration of the reject pulse can be set.

The intensity of the reject pulse can be set with the flow control screw

aJ.

1. Screw in the flow control screw

aJ as far as possible by turning it in a clockwise direction.

è

The channel of the reject pulse is then closed. No reject pulse is generated.

2. Screw in the flow control screw completely until the necessary intensity of the reject pulse is

reached.

You can set the duration of the reject pulse in the EDIT mode (è chapter 6.3.3).

3. Test the settings of the reject pulse before commissioning.

Reducing the vacuum

OVEM−

Ū−CN/−ON

· Block the supply of compressed air by switching off (with −CN) or by switching on (with −ON) the input

voltage.

è

Vacuum connection

5 is pressurized. The work item detaches itself from the suction gripper.

OVEM−

Ū−CE/−OE

By switching off (with −CE) or by switching on (with −OE) the input voltage, the second solenoid valve

will be switched and a reject pulse will be generated.

è

Vacuum connection

5 is pressurized. The work item detaches itself from the suction gripper.

Note

If the input voltage is switched on during the reject pulse (with −CE) or switched off

(withĂ−OE), the solenoid valve will be switched to the basic position and the reject pulse

will therefore no longer be generated.

Note

If large suction cups are used, a vacuum independent of the device may be generated

due to the flow resistance in the suction cup when the cup rises fron the work item. This

can lead to the suction cup not being released from the work item despite a sufficiently

long duration of the reject pulse.

The input voltage should therefore not be switched off (with −CE) or switched on

(withĂ−OE) until just before the suction cup lifts up in order that the reject pulse is active

when the suction cup rises.