1 segment bars – Festo Генератор вакуума OVEM, дюймовый Benutzerhandbuch

Seite 82

Advertising
background image

OVEM

82

Festo ć OVEM ć 1004b English

6.1.1

Segment bars

Various states of the vacuum generator can be shown via defined symbols in the segment bars next to

the graphic display of the current measured value.

Symbols

Representation

Meaning

Segment below left and [A] light up

and [min] or [max] flashes

1)

Ĉ SHOW mode active

on the LCD display an extreme value of In A1

(vacuum) is shown

Ĉ EDIT mode active

Segment below right and [B] light

up and [_|¯¯|_] [msec] flashes

Ĉ SHOW mode active

the duration of the reject pulse is shown on the

LCD display

Marked segments light up

Ĉ SHOW mode active

Diagnosis: Pressurization and evacuation time

(è Fig. 23: )

Ĉ EDIT mode active

Marked segments flash

Ĉ TEACH mode active

Switching point of evacuation time max.

Switching point of pressurization time max.

Marked segments light up and

[Option] flashes

Ĉ EDIT mode active

ON: Air−save function active

OFF: Air−save function inactive

Marked segments light up and

[Lock] flashes

Ĉ EDIT mode active

Special menu (SPEC) is open, the safety code is

shown on the LCD display

Segment below right lights up

Ĉ RUN mode active

There is a signal at the switch input.

The segment switch input In also lights up

Ĉ EDIT mode: Duration of reject pulse

Segment right centre lights up

Ĉ RUN mode active

Ĉ Solenoid valve under vacuum flow

3. Segment from below in the

right−hand segment bar lights up

Ĉ RUN mode active

Ĉ Solenoid valve reject under vacuum flow

1)

Extreme values:

min = minimum measured value
max = maximum measured value

Tab. 12: Special symbols of the segment bars

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: